摘 要:簡介四噴嘴對置式氣化爐燒嘴冷卻水泵回路配置及聯(lián)鎖設置的情況,針對運行過程中出現(xiàn)的諸多問題,分析其原因,并采取了一系列優(yōu)化、改造措施,由此保障了氣化爐的長周期穩(wěn)定運行。
關鍵詞:氣化爐;燒嘴冷卻水泵;回路配置;聯(lián)鎖設置;問題分析;改造
中圖分類號:TQ545 文獻標志碼:B 文章編號:1003-6490(2014)06-0059-05
Revamp of the Gasifier Burner Cooling Water Pump Circuit and It's Interlock Optimization
YAN Jing-luan
[New Energy Phoenix(Tengzhou) Energy Co.,Ltd.,Tengzhou Shandong 277527,China]
Abstract: Describe the cooling water pump circuit configuration of opposed four-nozzles gasifier and it's interlock set. To solve many problems in the operation,analyze the causes and take a series of optimization,revamp measures. Thus long-term stable operation of the gasifier is guaranteed.
Key words:gasifier; burner cooling water pump; circuit configuration; interlock set;analyze problem; revamp
德士古工藝燒嘴是氣化裝置的關鍵設備,一般為三流道外混式設計,在燒嘴中煤漿被高速氧氣流充分霧化,以利于氣化反應。德士古燒嘴插入氣化爐燃燒室中,我公司正常生產(chǎn)狀況下,燒嘴承受1350 ℃左右的高溫;為防止燒嘴損壞,在燒嘴外側設置冷卻盤管,在燒嘴頭部設置水夾套,并由2臺燒嘴冷卻水泵、冷卻水槽、事故燒嘴水泵向燒嘴供應冷卻水,同時,系統(tǒng)設置了復雜的安全聯(lián)鎖。由于燒嘴冷卻水泵的電氣回路配置容量偏小,元器件選用國產(chǎn),聯(lián)鎖系統(tǒng)不完善,曾因長期高負荷運行和電氣產(chǎn)品的性能下降,出現(xiàn)電器元件發(fā)熱、設備回路誤動的問題,漸漸不能滿足燒嘴冷卻水泵長期滿負荷運行的需要。
1 燒嘴冷卻水泵回路及聯(lián)鎖簡介
1.1 燒嘴冷卻水系統(tǒng)
公司設有P1201A/B 2臺燒嘴冷卻水泵,型號 TSP100-150-340L,流量 144 m3/h,揚程 280 m;電機型號 YB315L-2,功率185 kW,轉速 2970 r/min。由燒嘴冷卻水泵加壓,冷卻水經(jīng)燒嘴冷卻水換熱器冷卻后送入4個工藝燒嘴的冷卻水盤管內(nèi),最后采用低進高出的形式進入燒嘴頭部的水夾套對其進行強制冷卻,從而達到保護燒嘴的目的。P1204事故燒嘴冷卻水泵1臺,型號 TSP50-100-340L,流量 72 m3/h,揚程 280 m;電機型號 YB315M-2,功率 132 kW,轉速 2970 r/min;在2臺燒嘴冷卻水泵出現(xiàn)故障時使用。
目前,公司共有3臺1500 t/d氣化爐,每臺氣化爐采用四噴嘴對置式設置,正常生產(chǎn)狀況為2臺氣化爐105%負荷運行、1臺氣化爐備用,日....